Detection of loss of grid event in distributed generation systems using pattern recognition

Reference Number
EP/J017116/1
Title
Detection of loss of grid event in distributed generation systems using pattern recognition
Status
Completed
Energy Categories
Other Power and Storage Technologies(Electricity transmission and distribution)
Research Types
Basic and strategic applied research
Science and Technology Fields
ENGINEERING AND TECHNOLOGY (Electrical and Electronic Engineering)
UKERC Cross Cutting Characterisation
Not Cross-cutting
Principal Investigator
Dr DJ Atkinson
Electrical, Electronic & Computer Eng
Newcastle University
Award Type
Standard
Funding Source
EPSRC
Start Date
31 October 2012
End Date
30 April 2016
Duration
42 months
Total Grant Value
£238,489
Industrial Sectors
Energy
Region
North East
Programme
Energy : Engineering
Investigators
Principal Investigator
Dr DJ Atkinson, Electrical, Electronic & Computer Eng, Newcastle University
Other Investigator
Dr M Armstrong, Electrical, Electronic & Computer Eng, Newcastle University
Industrial Collaborator
Project Contact, Turbo Power Systems Ltd
Project Contact, Scottish and Southern Energy plc
Web Site
Objectives
Abstract
There is an urgent need to expand the use of renewable energy generation systems to meet UK government targets. The expansion of grid-connected renewable energy sources must be done in a way which does not reduce the security of the power distribution system. Integral to power distribution system security is the ability of distributed generators to reliably detect a loss of grid condition. This is important to prevent unwanted islanded sections of the system which continue to be energised after the grid connection is lost. An islanding system occurs when a part of the grid system become disconnected from the rest of the network but continues to be energised by localised distributed generation systems. Islanded systems are (i) potentially hazardous to power system workers, (ii) may operate outside voltage and frequency tolerance, (iii) may be inadequately grounded and (iv) may not re-synchronise properly leading to undesirable protection trips.The existing approaches to islanding detection either have operational regions in which they fail to work or are required to have artificial signals injected into the grid which can impact on power quality. The most difficult operational condition is when there is a power balance between a distributed generator and its local load network. During this condition many systems will not detect that the grid connection has been lost because the fundamental frequency quantities are not altered by the event.Many renewable generation systems require a grid-connected inverter to transfer power into the grid. This is necessary because the generating source itself is rarely capable of producing power at grid frequency. A grid-connected inverter must be able to detect the loss of grid event. This proposal will investigate a novel approach using pattern recognition with a high sampling rate. The pattern recognition system is required to analyse the inverter output voltages and currents to determine if a loss of grid event has taken place. The novelty in this proposal is to include the high frequency information due to PWM effects in the real-time analysis. The benefit of doing this is that information will still be available to the pattern recognition system when a power balance condition exists.There is concern that many islanded detection systems are not immune from the effects of other neighbouring equipment. This equipment may be power electronic loads or other grid-connected inverters. The basis of the proposed approach is that the pattern recognition system will be able to discriminate between the presence and absence of the grid connection despite potential interference signals from neighbouring equipment. A major advantage of the proposed scheme is that it makes use of high frequency signals generated by the PWM switching in the inverter. These signals are extracted from the output voltages and currents by using high sampling rates where a number of samples are taken during one PWM cycle. These signals will still be present when a balance load condition exits and therefore will provide valuable diagnostic information during this difficult condition. These high frequency signals will add to the signals associated with the fundamental frequency components to detect the loss of grid event.It is important that this scheme is demonstrated experimentally and therefore a test rig will be produced which contains a range of typical loads and other grid-connected generators. The rig will be used to evaluate the performance of the proposed scheme in the presence of other neighbouring power electronic equipment.If successful the research will have major impact on the integration of renewable energy generation into power distribution systems. There will be significant benefits to power distribution system security and to the manufacturers of grid-connected inverters