Projects: Summary of Projects by RegionProjects in Region Scotland involving University of Edinburgh : DTI/CC/133 |
||
Reference Number | DTI/CC/133 | |
Title | Optimisation of Furnace Design for In-Furnace NOx Reduction | |
Status | Completed | |
Energy Categories | Other Power and Storage Technologies(Electric power conversion) 20%; Fossil Fuels: Oil Gas and Coal(Coal, Coal combustion) 80%; |
|
Research Types | Applied Research and Development 100% | |
Science and Technology Fields | ENGINEERING AND TECHNOLOGY 100% | |
UKERC Cross Cutting Characterisation | Not Cross-cutting 100% | |
Principal Investigator |
Mr GJ Hesselmann No email address given Technology Centre Babcock International Group plc |
|
Award Type | 3 | |
Funding Source | DTI | |
Start Date | 01 January 2000 | |
End Date | 01 December 2001 | |
Duration | 23 months | |
Total Grant Value | £126,780 | |
Industrial Sectors | ||
Region | London | |
Programme | ||
Investigators | Principal Investigator | Mr GJ Hesselmann , Technology Centre, Babcock International Group plc (99.999%) |
Other Investigator | Project Contact , University of Edinburgh (0.001%) |
|
Web Site | ||
Objectives |
|
|
Abstract | Retrofit installations of low NOx systems are often constrained to some extent by the configuration of the existing plant. These practical constraints can be avoided in the design process for new plant. Factors such as the size, number and pitching of burners are selected to optimise furnace performance in terms of heat input, residence time, corrosion, pollutant formation and economics. The identification of optimum burner size and pitch with particular regard to NOxemissions and carbon burnout is The complex process of coal combustion can be simulated with some degree of accuracy by means of Computational Fluid Dynamics (CFD) modelling. This represents a valuable technique for the analysis of the effect of various factors on combustion performance and pollutant (NOx) formation. A review of existing front and opposed wall furnace designs found that for furnace sizes of 300 and 500 MWe, the typical thermal ratings of the burners employed are between 40 and 60 MWth. A non-dimensionalised horizontal, vertical and wall clearance pitch value of around 2.75d (2.75 x throat diameter) was representative of the units examined, with a number of units featuring burners having considerably tighter pitches (around 2d). The review also allowed the specification of the dimensions of generic furnaces for modelling purposes. Physical modelling of utility furnaces can be undertaken to obtain accurateflow measurement data. Data was obtained from a 1/10th scale perspex model of a generic front wall fired furnace. The measured data was used to validate the use of CFD techniques to investigate the effect of changes to furnace configuration. The effect of the variation of the number and size of burners was investigated in a front and an opposed wall fired furnace. Results established that fewer large burners are preferable to a larger number of smaller burners in terms of lower NOx (fuel and thermal) and plant economics, without adversely affecting carbon in ash (CIA). The predictions were consistent with previous studies of the effect of scaling criteria. Air biasing or off-stoichiometric firing was also investigated. NOx reductions predicted were poor, in line with plant experience. As pitch was reduced in a generic opposed wall fired furnace, flames became narrower, with a merging of tertiary air streams, a lessening in strength of the internal recirculation zone and a flaring out of flow to occupy available volume. Although fuel NOx showed little variation with reducing pitch, thermal NOx and CIA increased. The minimum acceptable pitch was identified. An additional study showed the sensitivity of fuel NOx to excess air level, and predictions from the CFD model were consistent with plant experience. The novel technique of burner interleaving in opposed wall fired furnaces was e valuated.Significant NOx reductions were gained through vertical interleaving but at the expense of higher CIA. The analysis of the design of the OFA systems applied to the front and opposed wall fired furnaces gave reductions in NOx comparable with expectations. Little or no NOx reduction benefit can be expected to accrue from the use of interleaving on opposed wall fired furnaces with deeply staged OFA systems, as staging becomes the limiting factor for NOx generation. | |
Data | No related datasets |
|
Projects | No related projects |
|
Publications | Optimisation of Furnace Design for In-Furnace NOx Reduction: Project Summary |
|
Added to Database | 01/01/07 |