Abstract:
<p>This document is a closedown report for the project titled 'Alternative Jointing Techniques for Small Diameter PE Pipe'.</p> The primary objectives of this stage are to: <ol> <li>Conduct a gap analysis to compare the requirements of Standards that selected fittings conform to, with the requirements of established UK Gas Industry Standards.</li> <li>Demonstrate, under laboratory conditions, the assembly of all mains-to-meter mechanical fittings from 4 different manufacturers and compare against a conventional electrofusion mains-to-meter assembly.</li> <li>Undertake laboratory tests of selected fittings for both leak tightness and pull-out resistance.</li> <li>Undertake a cost benefit analysis and undertake field observations. </li> </ol> </br> This report covers the project's: <bl> <li>Scope</li> <li>Objectives</li> <li>Success Criteria</li> <li>Performance Compared to the Original Project Aims, Objectives and Success Criteria</li> <li>Required Modifications to the Planned Approach During its Course</li> <li>Lessons Learnt for Future Projects</li> <li>Outcomes</li> <li>Planned Implementation</li> </bl>Publication Year:
2014
Publisher:
Ofgem
DOI:
No DOI minted
Author(s):
National Grid Gas Distribution
Energy Category
Class Name:
Subclass Name:
Category Name:
Language:
English
File Type:
application/pdf
File Size:
51037 B
Rights:
Rights not recorded
Rights Overview:
Rights are not recorded within the edc, check the data source for details
Further information:
N/A
Region:
United Kingdom
Related Dataset(s):
No related datasets
Related Project(s):
Related Publications(s):