Combustion in Power Station Boilers - Advanced Monitoring Using Imaging

This resource links to a document we hold in our system

Abstract:

Objectives of project:

  • To develop self-illuminated video (SIV) and image analysis techniques to identify adverse combustion conditions in utility PF boilers.
  • To provide a number of quantifiable parameters from video images which can be used to evaluate flame stability and combustion.
  • To develop PC software to transfer key parameters to existing data logging systems in real-time.
  • To develop systems to transmit and integrate video data from a number of cameras, under actual boiler plant conditions.
  • To determine optimum video probe designs and locations for quantitative SIV on utility boilers.
  • This report is divided into the following sections:
    1. Technical Background
    2. Project Objectives and Achievements
    3. Techniques and Results
    4. Conclusions and Future Work